Standard DMM that Delivers Top Safety and Reliability - General Purpose Testers with Rich Measurement Functions
The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The DT4256 is a digital multimeter designed to deliver maximum functionality for use in a wide range of settings.
CAT IV 600 V, CAT III 1000 V
• ±0.3% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics
• Measure up to 10A with direct input
• Dual display lets you check voltage and frequency simultaneously
• Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
• USB communications function supports PC measurements (optional)
• Broad -25 (-13°F) to 65°C (149°F) operating temperature range (DT4256)
![]() |
Multifunctional digital multimeter・ DC current 60.00mA / 600.0mA / 6.000A / 10.00A ・Accepts an AC clamp sensor. ・ Voltage detection function |
![]() |
Measure output voltage on the secondary sides of inverters by
|
![]() |
Measurement data can be downloaded to, reviewed on, and saved to a computer.If you connect the DT4255 to a computer with the optional Communication Package |
![]() |
True RMS measurement for accurate measurement of even distorted current waveformsDigital multimeters implement two types of measurement: mean-value measurement and |
![]() |
Designed and manufactured in Japan to ensure high quality and
|
![]() |
Safe measurement requires use of an instrument that suits the measurement location.To ensure operators’ ability to use measuring instruments safely, IEC 61010 classifies the |
DC Voltage range | 600.0 mV to 1000 V 5 ranges, Basic accuracy: ±0.3 % rdg. ±3 dgt. |
AC Voltage range | 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
AUTO AC/DCV | Yes |
Resistance range | 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±3 dgt. |
DC Current range | 60.00 mA to 10.00 A, 4 ranges, Basic accuracy: ±0.9 % rdg. ±3 dgt. |
From 4 to 20mA Percentage conversion display | 600.0 mA to 10.00 A, 3 ranges, Basic accuracy 40 - 500 Hz : ±1.4 % rdg. ±3 dgt. (True RMS, crest factor 3, 40 Hz to 1 kHz) |
AC Current range (use with Clamp on probes) | 10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 - 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
Voltage detection | Hi: AC40 V to 600 V, Lo: AC80 V to 600 V |
Capacitance range | 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt. |
Frequency range | 99.99 Hz to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage), Basic accuracy: ±0.1 % rdg. ±1 dgt. |
Continuity check | Continuity threshold [ON]: 25 Ω or less , [OFF]: 245 Ω or more, Response time: 0.5 ms or more |
Diode test | Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V |
Other functions | Filter function, Display value hold, Auto hold, Max/Min/Average value display, Relative display, Auto-power save, USB communication (option) |
Display | Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph |
Display refresh rates | 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s ) |
Power supply | LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF) |
Dimensions and mass | 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D, 390 g (13.8 oz) (including batteries and holster) |
Accessories | Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4 |